The intelligent power distribution room system is a system integrating electrical engineering design, construction, power transformation and distribution, safely use electricity, power monitoring, intelligent operation and maintenance, and environmental monitoring of the power distribution room.
Login SystemWith the development of social economy, the energy field is facing an increasingly severe test. On the one hand, the demand and dependence of social and economic activities on energy are increasing year by year; On the other hand, the severe global climate and environmental situation and the strict carbon emission control indicators proposed by countries around the world force the energy sector to make substantive changes and upgrades.
ROLINKPOWER ™ ‘s overall solution of intelligent power distribution station building of intelligent power system is committed to continuously applying advanced Internet of Things, digital perception, cloud computing and other technologies to the comprehensive and full cycle fine monitoring and automatic management of large-scale power distribution station building, and finding the operation status and energy consumption breakdown data of power distribution station building equipment in a meticulous manner, so as to help users find direct and indirect energy consumption hotspots, Predict potential safety hazards of equipment, reduce equipment consumption and labor consumption, and then systematically help users achieve the core goal of safety, low consumption and low carbon emission reduction.
ROLINKPOWER ™’s overall solution of intelligent power distribution station building of intelligent power system is divided into three layers: cloud, edge equipment and terminal intelligent equipment, as shown in the figure below.
The solution deeply integrates intelligent primary power distribution equipment with data platform, and integrates intelligent high-voltage switchgear, intelligent transformer, intelligent capacitor compensation switchgear and intelligent low-voltage switchgear. Through operation data monitoring, operation fault early warning, electrical fire early warning, environmental monitoring, intelligent operation and maintenance multi-dimensional early warning and monitoring functions and station building power equipment linkage control functions, ensure the safe operation of electric equipment, achieve distributed remote management of the distribution station building, reduce personnel input, accurately and timely find equipment hidden dangers, reduce losses, at the same time find energy hot spots, reduce energy consumption, In order to achieve the goal of systematically improving efficiency, saving energy and reducing carbon emissions.
No. | Equipment Type | Equipment Name | Equipment Model |
---|---|---|---|
1 | Intelligent high-voltage switchgear (middle placed) | Integrated Protection Device | LY-P200 |
Intelligent Control | LY-SD20 | ||
Partial Discharge Monitoring Device | LY-MD500 | ||
Multifunctional Instrument | Optional According to Real Requirement | ||
Wireless Temperature Measuring Device | LY401 | ||
2 | Intelligent high-voltage switchgear (ring network switchgear) | Wireless Measurement and Control Terminal | ICS-X100 |
Integrated Protection Device | ICS-A100 | ||
Partial Discharge Monitoring Device | LY-MD500 | ||
Intelligent Temperature and Humidity Monitoring | LY-ZWSK | ||
Wireless Temperature Measuring Device | LY401 | ||
3 | Intelligent Transformer | Intelligent Transformer Controller | Optional According to Real Requirement |
Transformer Noise Sensor | LY-ZS01 | ||
4 | Intelligent low-voltage switchgear(frame) | Intelligent Frame Circuit Breaker | CKW65 |
Multifunctional Instrument | Optional According to Real Requirement | ||
Wireless Temperature Measuring Device | |||
5 | Intelligent low-voltage switchgear(plastic case) | Intelligent plastic case circuit breaker | CKM68 |
Guide rail multi-function instrument | Optional according to Real Requirement | ||
6 | Internet of Things centralized control switchgear in power distribution room | Standard Monitoring Switchgear | 800*600*2200 (mm) |
Intelligent Gateway | CMU-A5000 | ||
Hardware Video Recorder | NVR DS-7708N-K4 | ||
Exchanger | Optional according to Real Requirement | ||
Monitor | Optional according to Real Requirement | ||
Power Management System | Optional according to Real Requirement | ||
7 | Environmental Monitoring Terminal | Temperature and Humidity Sensor | LY-WK01 |
Water Immersion Sensor | LY-SJ01 | ||
Smoke Sensor | LY-YW01 | ||
SF6 Gas Sensor | LY-SF601 | ||
Ozone Sensor | LY-CY01 | ||
Air Quality Sensor | LY-KQZL01 | ||
Infrared Sensor | LY-HW01 | ||
Wind Machine Linkage Device | LY-FJ01 | ||
Light Linkage Device | LY-DG01 | ||
Pump Linkage Device | LY-SB01 | ||
Air Conditioner Linkage Device | LY-KT01 | ||
8 | Video Monitoring Terminal | Ball Camera | iDS-2DC4223IWQJ |
Gun Camera | DS-2CD2T26EWDQA-L | ||
Patrol Robot | Optional According to Real Requirement |
Real time data monitoring, robot independent inspection, video monitoring and auxiliary dynamic ring system solve the problem of power distribution system operation and maintenance, save manpower and ensure personnel safety.
The equipment information is collected independently and reported actively, and the system conducts intelligent research and judgment. The equipment early warning, alarm and fault information are handled according to levels and authorities.
Integrate the comprehensive data such as the detection information of high and low voltage equipment and auxiliary control system in the power distribution system, the expert system makes independent research and judgment, and pushes the abnormal problems hierarchically.
The electrical preventive test shall be carried out periodically by issuing patrol inspection, defect elimination tasks and on-site patrol inspection. Realize the full link closed-loop of "intelligent perception - event linkage - cooperative operation and maintenance - source tracing analysis".
Intelligent switchgear manufacturing base:
Office telephone: 0519-8602-9925
Company Email: switch@rolink.com.cn
No. 101, Yong'anli Road, Luoyang Town, Wujin District, Changzhou City, Jiangsu Province
Power Supply Internet of Things Technology Research Institute:
Office telephone: 029-8114-1058
Company Email: rolinkpower@rolink.com.cn
Building B, CIC International, Jinye 1st Road, High tech Zone, Xi'an, Shaanxi