RolinkPower ™ Intelligent equipment covers power transformation and distribution automation products, power equipment online monitoring products, environmental sensors in power transformation and distribution stations Video security, electrical fire and energy efficiency monitoring. All intelligent devices can use local wireless network without charge, Ethernet or RS485 and other communication networks, connect the intelligent power cloud platform through the edge gateway, and build a complete intelligent Internet of Things energy management system.

Location:Home > Products > Power transformation and distribution automation products
Power transformation and distribution automation products
Online monitoring device
Environmental sensor
Video and Security
Electrical fire
Energy efficiency management

LY-D611 distribution automation terminal common unit

1c0fcccd137ad531ad5c87439572161b.jpg
Product Overview
Major Function
Technical Parameter

LY-D611 distribution automation terminal public unit, which meets the requirements of the technical specification of the national grid primary and secondary integration network cabinet, is a component of the distributed DTU. It is applicable to 10kV distribution automation system. The distribution automation terminal is composed of several LY-D612 distribution automation terminal interval units and LY-D611 distribution automation terminal common units. Each unit of the distribution automation terminal adopts a small structure, which is conducive to decentralized installation into the ring network cabinet.

Characteristic

◇ The device adopts 32-bit high-performance ARM processor, which has fast operation processing, parallel data acquisition and data calculation processing, and 16 bit high-precision external A/D chip for AC sampling. It has strong communication management capability and provides multiple independent network channels. It supports RS-232, RS-485, Ethernet and other communication interfaces, as well as IEC60870-5-101/104, IEC61850-MMS, IEC61850-GOOSE and other communication protocols. It can realize real-time interactive communication between terminals and fast location of distribution power grid faults.

◇ The device adopts high-precision clock chip inside, and has the function of receiving SNTP network timing from the distribution master station.

◇ When the backup power management device is configured externally, the device can realize the collection functions of battery voltage information, external power supply loss, battery failure, battery charging failure, etc., and has the remote battery activation function.

◇ The device has self diagnosis and self recovery functions. It can self diagnose various functional boards and important chips, report abnormal information, and automatically reset software abnormalities.

◇ The device has the local and remote configuration function of unit operation parameters, including zero threshold (zero drift), change threshold (dead zone), heavy overload alarm limit, short circuit and ground fault action parameters.

◇ The device has the function of local and remote access to the inherent parameters of the unit. The access parameters include terminal type and factory model, terminal ID number, embedded system name and version number, hardware version number, software verification code, communication parameters, secondary transformation ratio, etc.

◇ The device has the function of cyclic storage of historical data. The saved data will not be lost after power loss. It supports remote reading. The historical data includes remote signaling displacement with time scale, remote control operation records, daily frozen electricity, fixed point data, extreme value data, etc.


◇ LY-D611 public unit of distribution automation terminal is a component of distributed DTU system, which is used together with DTU interval unit.

◇ Collect remote signaling data, telemetry data, protection events, wave recording data, operation status, electrical parameter data and other relevant information of each DTU interval unit, and transmit them to the master station remotely.

◇ The public unit of the power distribution automation terminal obtains the remote control command issued by the master station and conducts remote control operation on each DTU interval unit.

Main parameter

Application


  Rated operating voltage

  DC24V/48V(Adaptive, input range -20%~20%)


  Nominal value of AC voltage input

  5A/1A (Description when ordering


  Nominal value of AC voltage input

  100V


  Frequency range

  45~55Hz

Rating value

  Remote signaling power supply

  DC24V


  Contact capacity

  AC250V/10A/DC24V/16A/DC48V/8A


  Anti shake time of remote signaling software

  5~65000ms can be set


  Output contact life

  On/off ≧ 105 times


  AC sampling voltage,Current measurement accuracy

  0.5S


  Active power,Reactive power measurement accuracy

  Level 1


  Frequency measurement accuracy

  ±0.01


  SOE resolution ratio

  2ms


  Protection action time error

  <40ms


  Current and voltage fixed value error

  <3%

Accuracy

  Distributed FA information interaction time

  Quick motion type ≦ 20ms;  Slow motion type ≦ 200ms


  Distributed FA Troubleshooting time

  Quick motion type interval time ≦ 200ms;Slow motion type recovery 

  time of non fault area ≦ 45s


  Timing error and timing accuracy

  24H < 2s,The clock power is supplied by external power supply and 

  button battery, and the external power supply is preferred


  Corresponding time of remote signaling displacement

  ≦1s


  Change telemetry refresh time

  ≦3s


  Control command response time

  ≦2s


  Working power circuit

  <5W under normal <15Woperation,Control output action

Unit power consumption

  AC current loop

  Each phase ≦ 0.75VA


  AC voltage loop

  Each phase ≦ 0.5VA

Overload capacity

  Overload capacity of AC current circuit

  1.2In,Continuous operation; 20In,1s


  Overload capacity of AC voltage circuit

  1.2Un,Continuous operation; 20Un,1s

Insulation resistance

  10MΩ

Electromagnetic compatibility

  Level Ⅳ


Intelligent switchgear manufacturing base:

Office telephone: 0519-8602-9925

Company Email: switch@rolink.com.cn

No. 101, Yong'anli Road, Luoyang Town, Wujin District, Changzhou City, Jiangsu Province

Power Supply Internet of Things Technology Research Institute:

Office telephone: 029-8114-1058

Company Email: rolinkpower@rolink.com.cn

Building B, CIC International, Jinye 1st Road, High tech Zone, Xi'an, Shaanxi

Consulting hotline

0519-8602-9925

WeChat Official Account