RolinkPower ™ Intelligent equipment covers power transformation and distribution automation products, power equipment online monitoring products, environmental sensors in power transformation and distribution stations Video security, electrical fire and energy efficiency monitoring. All intelligent devices can use local wireless network without charge, Ethernet or RS485 and other communication networks, connect the intelligent power cloud platform through the edge gateway, and build a complete intelligent Internet of Things energy management system.
LY-D612 distribution automation terminal interval unit is a component of distributed DTU, which meets the requirements of the technical specifications of the national grid primary and secondary integrated ring cage. It is applicable to 10kV distribution automation system. The distribution automation terminal is composed of several LY-D612 distribution automation terminal interval units and LY-D611 distribution automation terminal common units. Each unit of the distribution automation terminal adopts a small structure, which is conducive to decentralized installation in the ring network cabinet.
Characteristic
◇ The device adopts 32-bit high-performance ARM processor, which has fast operation processing, parallel data acquisition and data calculation processing, and 16 bit high-precision external A/D chip for AC sampling. It has strong communication management capability and provides multiple independent network channels. It supports RS-232, RS-485, Ethernet and other communication interfaces, as well as IEC60870-5-101/104, IEC61850-MMS, IEC61850-GOOSE and other communication protocols. It can realize real-time interactive communication between terminals, fast fault location of distribution grids, fast local fault isolation, fast transfer of power supply loads, and fast self-healing power supply in non fault areas.
◇ It has perfect local FA logic function, which can realize the functions of fault monitoring, location, isolation and power transmission restoration in non fault areas. Support quick action and slow action distributed feeder automatic protection function based on peer-to-peer communication; Support voltage time type and voltage current type feeder automatic protection functions independent of communication; It has optical fiber longitudinal differential protection function.
◇ The device integrates control, monitoring, signal, communication, measurement, event recording, protection and other feeder automation functions.
◇ The device adopts high-precision clock chip inside, and has the function of receiving SNTP network timing from the distribution master station.
◇ The device has the function of fault recording and fault wave recording, supporting 64 groups of wave recording data to be stored circularly, sampling at 80 points per week, and recording 4 cycles before and 8 cycles after the fault; Wave recording files can be uploaded to the public unit through the network interface.
◇ The device has self diagnosis and self recovery functions. It can self diagnose various functional boards and important chips, report abnormal information, and automatically reset software abnormalities.
◇ The device has the local and remote configuration function of unit operation parameters, including zero threshold (zero drift), change threshold (dead zone), heavy overload alarm limit, short circuit and ground fault action parameters.
◇ The device has the function of local and remote access to the inherent parameters of the unit. The access parameters include terminal type and factory model, terminal ID number, embedded system name and version number, hardware version number, software verification code, communication parameters, secondary transformation ratio, etc.
◇ The device has the function of cyclic storage of historical data. The saved data will not be lost after power loss. It supports remote reading. The historical data includes remote signaling displacement with time scale, remote control operation records, daily frozen electricity, fixed point data, extreme value data, etc.
◇ LY-D612 distribution automation terminal interval unit is a component of the distributed DTU system and is used together with the DTU common unit.
◇ Be responsible for collecting the remote signaling data, telemetry data, protection events, wave recording data, operation status, electrical parameter data and other relevant information of the interval unit, and uploading them to the public unit.
◇ The DTU interval unit obtains the remote control command issued by the DTU common unit to realize the remote control operation function for each interval unit.
◇ The DTU interval unit integrates the centralized FA and local FA protection functions of the main station, and can realize such logic functions as microcomputer integrated relay protection, optical fiber differential protection, voltage time type feeder automation protection, voltage current type feeder automation protection, etc.
◇ Realize fast fault location, fault removal, fault isolation and load transfer of distribution grids, and quickly recover power supply in non fault areas.
Main parameter | Application | |
Rated operating voltage | DC24V/48V(Adaptive, input range -20%~20%) | |
Nominal value of AC voltage input | 5A/1A (Description when ordering | |
Nominal value of AC voltage input | 100V | |
Frequency range | 45~55Hz | |
Rating value | Remote signaling power supply | DC24V |
Contact capacity | AC250V/10A/DC24V/16A/DC48V/8A | |
Anti shake time of remote signaling software | 5~65000ms can be set | |
Output contact life | On/off ≧ 105 times | |
AC sampling voltage,Current measurement accuracy | 0.5S | |
Active power,Reactive power measurement accuracy | Level 1 | |
Frequency measurement accuracy | ±0.01 | |
SOE resolution ratio | 2ms | |
Protection action time error | <40ms | |
Current and voltage fixed value error | <3% | |
Accuracy | Distributed FA information interaction time | Quick motion type ≦ 20ms; Slow motion type ≦ 200ms |
Distributed FA Troubleshooting time | Quick motion type interval time ≦ 200ms;Slow motion type recovery time of non fault area ≦ 45s | |
Timing error and timing accuracy | 24H < 2s,The clock power is supplied by external power supply and button battery, and the external power supply is preferred | |
Corresponding time of remote signaling displacement | ≦1s | |
Change telemetry refresh time | ≦3s | |
Control command response time | ≦2s | |
Working power circuit | <5W under normal <15Woperation,Control output action | |
Unit power consumption | AC current loop | Each phase ≦ 0.75VA |
AC voltage loop | Each phase ≦ 0.5VA | |
Overload capacity | Overload capacity of AC current circuit | 1.2In,Continuous operation; 20In,1s |
Overload capacity of AC voltage circuit | 1.2Un,Continuous operation; 20Un,1s | |
Insulation resistance | 10MΩ | |
Electromagnetic compatibility | Level Ⅳ |
Intelligent switchgear manufacturing base:
Office telephone: 0519-8602-9925
Company Email: switch@rolink.com.cn
No. 101, Yong'anli Road, Luoyang Town, Wujin District, Changzhou City, Jiangsu Province
Power Supply Internet of Things Technology Research Institute:
Office telephone: 029-8114-1058
Company Email: rolinkpower@rolink.com.cn
Building B, CIC International, Jinye 1st Road, High tech Zone, Xi'an, Shaanxi