Intelligent control equipment

RolinkPower ™ Intelligent equipment covers power transformation and distribution automation products, power equipment online monitoring products, environmental sensors in power transformation and distribution stations Video security, electrical fire and energy efficiency monitoring. All intelligent devices can use local wireless network without charge, Ethernet or RS485 and other communication networks, connect the intelligent power cloud platform through the edge gateway, and build a complete intelligent Internet of Things energy management system.

Location:Home > Products > Energy efficiency management
Power transformation and distribution automation products
Online monitoring device
Environmental sensor
Video and Security
Electrical fire
Energy efficiency management

DDSU-XXX single-phase guide rail electronic energy meter

df4772858b586f06d0837b32fb9b8ad3.jpg
Product Overview
Technical parameter
Overall dimensions
Product Selection Table

The single-phase guideway electronic energy meter is designed with advanced energy metering chip and mature software technology, and is used to measure single-phase AC active energy with a frequency of 50Hz/60Hz. Each performance index of this product meets the relevant technical requirements of GB/T17215.321-2008 Class 1 and Class 2 Static AC Active Energy Meters; The 8-bit LCD display shows the functional power consumption. It has the characteristics of good reliability, small size, light weight, beautiful appearance, advanced technology, 35mm DIN standard rail installation, etc.; it also has good electromagnetic interference resistance, low self consumption and power saving, high precision, high overload, high stability, power theft prevention, and long life. It is used for fixed installation indoors, and is applicable to the environment temperature not exceeding - 25~+55 ℃, the relative humidity not exceeding 95%, and the air does not contain corrosive gas and avoid the impact of dust, mold, salt fog, condensation, insects, etc.


1. Main technical parameters

1.1 Error limit:

Basic error limit of electric energy meter with load


Load current

Power factor

Basic error (%)

Level 1

Level 2

0.05Ib

1.0

±1.5

±2.5

0.1IbImax

1.0

±1.0

±2.0

0.1Ib

0.5(lagging)

±1.5

±2.5

0.8(advance)

0.2IbImax

0.5(lagging)

±1.5

±2.5

0.8(advance)

1.2 Starting

At reference voltage, reference frequency and Under the condition of COS Φ= 1, when the primary meter is 0.4Ib% and the secondary meter is 0.5Ib%, the electric energy meter can start and continuously measure electric energy.

1.3 Latency

When there is no current in the current circuit of the electric energy meter and the voltage applied to the voltage circuit is 115% of the rated value, the test output of the electric energy meter shall not generate more than one pulse.

1.4 Insulation performance

All lines of the electric energy meter can withstand the waveform of 1.2//50 μ s between the shells. The pulse voltage with a peak value of 6KV shall be tested for 10 times continuously under different polarities without arc discharge or breakdown. All lines of the electric energy meter can withstand an AC voltage of 2KV of 50Hz actual sinusoidal waveform between the meter case or the accessible metal parts outside the meter case, and the test lasts for one minute without breakdown.

1.5 Working voltage limit: 70%~130% Ub

1.6 Power consumption: ≤ 2W and 10VA

1.7 Display: LCD display

1.8 Data storage: after power failure, the data shall be stored for at least 10 years.


11111.png

dbced02f937796a1d93dd01d71bd2f0.jpg

Intelligent switchgear manufacturing base:

Office telephone: 0519-8602-9925

Company Email: switch@rolink.com.cn

No. 101, Yong'anli Road, Luoyang Town, Wujin District, Changzhou City, Jiangsu Province

Power Supply Internet of Things Technology Research Institute:

Office telephone: 029-8114-1058

Company Email: rolinkpower@rolink.com.cn

Building B, CIC International, Jinye 1st Road, High tech Zone, Xi'an, Shaanxi

Consulting hotline

0519-8602-9925

WeChat Official Account