RolinkPower ™ intelligent power complete equipment covers intelligent box transformer, intelligent ring network switchgear, intelligent central switchgear, intelligent transformer and intelligent compensation switchgear,power complete equipment and key components required for the above complete equipment. We rely on more than 50 years of experience in the power industry and large-scale, serialization of digitalized processing base on electric power equipment, we provide our users complete, safe, reliable and cost-effective electric power equipment services.

Location:Home > Products > Intelligent central cabinet
Intelligent central cabinet
Intelligent low-voltage cabinet
Smart box transformer

CKD2000B-12 Series solid sealed pole type indoor High Voltage Vacuum Circuit Breaker with Sealed Pole

CKD-2000B.jpg
Product Overview
Technical parameter
Applicable conditions

CKD2000B-12 series solid sealed pole indoor high-voltage vacuum circuit breaker is a three-phase 50Hz AC indoor high-voltage electrical device with a rated voltage of 12kV. It is mainly installed in the central handcart switchgear, and can also be installed in the fixed switchgear. It is used for the control and protection of electrical facilities in industrial and mining enterprises, power plants and substations, and is especially suitable for places with frequent operations.


Executive standard:

  GB1984-2003 AC High Voltage Circuit Breaker (China standard)

  JB3855-1996 3.6-40.5kV Indoor AC High Voltage Vacuum Circuit Breaker (Rolink standard)

  IEC62271-110:2001 AC High Voltage Circuit Breaker (Rolink standard)

  DL/T403-2000 Technical Conditions for Ordering 12-40.5kV High Voltage Vacuum Circuit Breaker (Rolink standard)



No.NameUnitParameter value
1Rated voltagekV12
2Rated insulation level1min Power frequency withstand voltage (effective value)42
Rated lightning impulse voltage (peak value)75
3Rated short-circuit breaking currentkA2531.540
4Rated short-circuit closing current (peak value)6380100
5Rated short-time withstand current2531.540
6Rated peak value withstand current6380100
7Rated currentA630, 12501250, 16002000, 2500, 3150, 4000
8Rated single capacitor bank breaking current630
9Rated back to back capacitor bank breaking current400
10Rated back to back capacitor bank closing inrush currentkA200 (Frequency no more than 4250Hz)
11Rated short circuit durations4
12Rated frequencyHz50
13
Life of the mechanismtimes10000


Applicable conditions

1. Ambient temperature: maximum temperature+40 ℃, minimum temperature - 10 ℃.

2. Ambient humidity: daily average relative humidity ≤ 95%;

Monthly average relative humidity ≤ 90%;

Daily average saturated steam pressure ≤ 2.2 ✖ 10-3Mpa;

Monthly average saturated steam pressure ≤ 1.8 ✖ 10-3Mpa.

3. Altitude:<4000m.

4. The earthquake intensity shall not exceed magnitude 8.

5. The place of use shall be free from flammable, explosive, chemical corrosion and violent vibration.


Intelligent switchgear manufacturing base:

Office telephone: 0519-8602-9925

Company Email: switch@rolink.com.cn

No. 101, Yong'anli Road, Luoyang Town, Wujin District, Changzhou City, Jiangsu Province

Power Supply Internet of Things Technology Research Institute:

Office telephone: 029-8114-1058

Company Email: rolinkpower@rolink.com.cn

Building B, CIC International, Jinye 1st Road, High tech Zone, Xi'an, Shaanxi

Consulting hotline

0519-8602-9925

WeChat Official Account